SERVICES
We design, install, inspect, test, repair, and maintain fire and life safety systems to meet NFPA, CAN/ULC, and Ontario Building Code (OBC) requirements. All programs are tailored to your site and industry.
Inspection & Testing (NFPA / CAN/ULC Compliant)
Inspection & Testing (NFPA / CAN/ULC Compliant)
- Weekly, monthly, quarterly, and annual inspections per NFPA and CAN/ULC requirements
- Comprehensive programs covering alarms, sprinklers, special hazards, hydrants, lighting, extinguishers, hoses, pumps, and backflow
- Deficiency and repair tracking with AHJ ready reports
- Laboratory sprinkler testing and annual foam analysis
Fire Alarm Systems (NFPA / CAN/ULCS536)
Fire Alarm Systems (NFPA / CAN/ULCS536)
- Annual and monthly inspections and reporting
- Conventional and addressable fire alarm systems
- Pre-action and agent releasing systems
- Panic systems and integrated voice communication
- 24/7 emergency support
- CFAA certified technicians providing detailed, ULC compliant reports (typically within 24 hours of inspection)
Inspection cadence:
- Daily: Check AC power lamp and trouble light indicators.
- Monthly: Test alarm functions and communications; inspect smoke alarms as per manufacturer and NFPA recommendations.
- Annually: Full CAN/ULCS536 inspection, voice communication testing, and AHJ compliance review.
Sprinkler Systems (NFPA 25 / OBC)
Sprinkler Systems (NFPA 25 / OBC)
- Annual, monthly, quarterly, and weekly testing, inspection, and reporting
- Wet, dry, deluge, and pre-action systems; standpipe systems and hydrants
- Diesel and electric fire pump inspection, testing, and maintenance
- Weekly control valve position verification (unsupervised valves)
- Periodic trip tests for dry systems, valve/inlet inspection, and five-year flushing
Cadence highlights:
- Weekly: Verify unsupervised control valves; check dry system air/water pressures.
- Monthly: Test alarms on systems without electrical supervisory service; inspect lockedopen valves.
- Quarterly/Annual: Full NFPA 25 inspection and water flow testing.
- Every 3 years: Dry-pipe valve trip test with control valve fully open.
- Every 5 years: System flushing.
Fire Extinguishers (NFPA 10) & Fire Hoses (NFPA 25)
Fire Extinguishers (NFPA 10) & Fire Hoses (NFPA 25)
- Supply of new NFPA/CANULC portable extinguishers and hose cabinets
- Annual and monthly site inspections and reporting
- Recharging and hydrostatic testing
- ULC & Transport Canada-approved requalification facility
- N2 and CO2 cartridge refilling
- Fire hose hydrostatic testing and recoupling
- Recycling and refurbishment
Inspection cadence (NFPA):
- Extinguishers (NFPA 10 Monthly): Quick check for readiness, record on tag.
- Extinguishers (NFPA 10 Annually): Full preventative maintenance by qualified technician.
- Hydrostatic testing (NFPA 10 / 25) at defined lifecycle intervals based on type.
Hydrants & Backflow Prevention (NFPA 25)
Hydrants & Backflow Prevention (NFPA 25)
- Annual testing and certification
- Installation, repairs, and maintenance
- Flow and pressure testing per NFPA 25
Emergency Lighting & Exit Signs (NFPA 101 / CAN/ULC)
Emergency Lighting & Exit Signs (NFPA 101 / CAN/ULC)
- Annual and monthly inspections and reporting
- Exit lighting, emergency power units, remotes, and inverters
- Lamp and battery replacement; documented test logs
Special Hazard Systems
Special Hazard Systems
- Clean agent suppression inspection/service
- Integration with alarms and monitoring
- Programmed testing to minimise disruption
Monitoring Services
Monitoring Services
- 24/7 system monitoring with remote diagnostics
- Custom notifications and automatic dispatch
- Secure compliance documentation
Fire & Life Safety Training
Fire & Life Safety Training
- Instructional live fire training
- Classroom safety training
- NFPA-aligned courses on portable extinguisher use and emergency readiness
Property & Facility Management
Property & Facility Management
We provide ongoing inspections, testing, and maintenance for some of Canada’s leading property management firms, including:
CBRE • BGIS • Rogers • Triovest • Colliers • Mantella Corporation • Bentall Green Oak
…plus various other property managers in commercial, industrial, and mixed-use sectors.
We work closely with facility teams to plan inspections and repairs around operational schedules — whether it’s an urban office tower, an industrial warehouse, or a multi-tenant retail plaza.
Corporate & Commercial
Corporate & Commercial
Corporate offices, telecom facilities, and commercial buildings trust Direct Life Safety for Fire Alarm and Sprinkler services that minimise disruption and keep team members and visitors safe.
Industrial & Warehousing
Industrial & Warehousing
We manage large-footprint inspections and maintenance for warehouses, distribution centres, and manufacturing plants — ensuring compliance with NFPA, Ontario Building Code (OBC), and AHJ requirements.
Healthcare & Data Centres
Healthcare & Data Centres
From hospitals to critical IT facilities, we adapt service programs to meet strict operational and uptime requirements, including infection control protocols and special hazard suppression systems.
Contracting & Construction
Contracting & Construction
In addition to inspection work, our Sprinkler and Fire Alarm contracting division partners with:
- Electrical Partners— Integrated alarm, suppression, and monitoring installations.
- General Partners— New builds, retrofits, and tenant improvement projects.
We act as the fire protection specialist on complex builds — bringing NFPAcompliant design, installation, and commissioning expertise to meet project timelines and quality standards.